TCZEL23056
Telecentric zoom lens for 2/3″ sensors with integrated liquid lens, manification range from 0.18x to 0.55x
Specifications
Downloads
Compatible products
Tech notes
Main optical specifications | ||
Magnification range | (x) |
0.180 0.550 |
Magnification ratio | (x) | 3 |
Image circle diameter | (mm) | 11.0 |
Max sensor size | 2/3″ |
Object field of view | ||
1/3” | (mm × mm) |
26.67 x 20.00 8.73 x 6.55 |
1/2.5” | (mm × mm) |
31.67 x 23.78 10.36 x 7.78 |
1/2” | (mm × mm) |
35.56 x 26.67 11.64 x 8.73 |
1/1.8” | (mm × mm) |
39.61 x 29.61 12.96 x 9.69 |
2/3” | (mm × mm) |
47.22 x 39.39 15.45 x 12.89 |
Advanced optical specifications | ||
Working distance range (1) | (mm) | 115 - 155 |
Working ƒ/N (2) |
9 16 |
|
Telecentricity max (3) | (deg) |
< 0.3 < 0.3 |
Distortion max (4) | (%) |
< 0.3 < 0.3 |
Depth of field (5) | (mm) |
14.40 2.70 |
Resolution (6) | (μm) |
32 18 |
Liquid lens specifications | ||
Number of lenses | 2 | |
Liquid lens model | Optotune EL-16-40-20D | |
Temperature sensor | Yes | |
Focal power mode | Yes | |
Response time (7) | (ms) | 5 |
Setting time (7) | (ms) | 25 |
Current range | (mA) | -500 to +500 |
Repeatability using focal power mode | (dpt) | ±0.05 (small steps); ±0.1 (large steps) |
Lifecycles (10%-90% sinusoidal) | >1,000,000,000 | |
Connector | HR10A-7R-6PB |
Mechanical specifications | ||
Mount | C | |
Phase adjustment (8) | Yes | |
Length (9) | (mm) | 249.3 |
Front diameter | (mm) | 80.0 |
Mass | (g) | 967 |
Environmental specifications | ||
Operating temperature | (°C) | 0-40 |
Storage temperature | (°C) | 0-50 |
Operating relative humidity | (%) | 20-85, non condensing |
Installation | Indoor use only |
Last update 26 Mar 2024
Notes
- Working distance: distance between the front end of the mechanics and the object, reported at nominal range of the liquid lenses; maximum excursion may be larger.
- Working f-number (wf/N): the real f-number of a lens in operating conditions.
- Maximum angle between chief rays and optical axis on the object side.
- Percent deviation of the real image compared to an ideal, undistorted image.
- At the borders of the field depth the image can be still used for measurement but, to get a perfectly sharp image, only half of the nominal field depth should be considered. Pixel size used for calculation is 3.45 μm.
- Object side, calculated with the Rayleigh criterion with λ= 520 nm
- Typical at 30°C, 0 to ±250 mA step.
- Indicates the availability of an integrated camera phase adjustment feature.
- Measured from the front end of the mechanics to the camera flange.
Additional notes
Performances guaranteed when used with vertical optical axis; when used with horizontal optical axis performances drop due to gravity induced aberrations of the liquid lens.Ordering information
Hirose cables and liquid lens controller sold separately.
All product specifications and data are subject to change without notice to improve reliability, functionality, design or other. Photos and pictures are for illustration purposes only.
Despite the efforts made to generate an error-free compatibility list, we always recommend to consult the Opto Engineering® technical support department before purchasing a compatible product. Opto Engineering® shall not be liable for any damage or malfunctioning caused by the incorrect selection of a compatible product.
ITA50-GM-10C
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Mono, 1 GigE, POE, C mount
ITA50-GC-10C
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Color, 1 GigE, POE, C mount
ITA50-GM-10C-PL
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Polar Mono, 1 GigE, POE, C mount
ITA50-GC-10C-PL
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Polar Color, 1 GigE, POE, C mount
ITA81-GM-20C
Area scan camera 2856 x 2848 MP, Sony IMX546, CMOS Global shutter, 2/3", Mono, 1 GigE, POE, C mount
ITA81-GC-20C
Area scan camera 2856 x 2848 MP, Sony IMX546, CMOS Global shutter, 2/3", Color, 1 GigE, POE, C mount
LTCLHP056-R
Telecentric HP illuminator, beam diameter 70 mm, red, 625 nm
LTCLHP056-G
Telecentric HP illuminator, beam diameter 70 mm, green, 525 nm
LTCLHP056-B
Telecentric HP illuminator, beam diameter 70 mm, blue, 460 nm
LTCLHP056-W
Telecentric HP illuminator, beam diameter 70 mm, white, 6000 K
LTRN056RD
Ring LED illuminator, inner diameter 80.0 mm, straight type, red, 630 nm
LTRN056GR
Ring LED illuminator, inner diameter 80.0 mm, straight type, green, 525 nm
LTRN056BL
Ring LED illuminator, inner diameter 80.0 mm, straight type, blue, 470 nm
LTRN056NW
Ring LED illuminator, inner diameter 80.0 mm, straight type, white, 6300 K
CMBS056
45° beam splitter with mount for 80.0 mm clamping diameter optics
CMMR056
45° first surface mirror for 80.0 mm clamping diameter optics
WI056
Protective window for 80 mm clamping diameter optics
CMHO056
Clamping mechanics for TCxx056 lenses and LTCLHP056-X illuminators
PT036-056
Calibration pattern
PT036-056-C
Checkerboard calibration pattern for telecentric lens with certificate
CMWF056
Holder for WI series, clamping diameter 80 mm
CBGPIO6PMF-3M
6 Pin Hirose Male - Female moulded connector cable, 3 m
Tech notes
Liquid Lens