Specifications
Downloads
Compatible products
Main optical specifications | ||
Magnification | (x) | 0.086 |
Image shape dimension (1) | (mm x mm) | 14.90 x 10.90 |
Max sensor size | 1.1″ |
Object field of view | ||
1/1.2″ | (mm × mm) | 132.28 x 83.10 |
1″ | (mm × mm) | 165.38 x 87.53 |
1.1″ | (mm × mm) | 165.03 x 120.86 |
1.3" | (mm × mm) | - |
4/3″ | (mm × mm) | - |
Advanced optical specifications | ||
Working distance (2) | (mm) | 232.0 |
Working ƒ/N (3) | 11 | |
Telecentricity typical (max) (4) | (deg) | < 0.06 (0.10) |
Distortion typical (max) (5) | (%) | < 0.8 |
Residual distortion (6) | (%) | < 0.01 |
Depth of field (7) | (mm) | 77.30 |
Resolution (8) | (μm) | 81 |
Mechanical specifications | ||
Mount | C | |
Phase adjustment (9) | Yes | |
Dimension A (10) | (mm) | 332 |
Dimension B | (mm) | 303 |
Dimension C (11) | (mm) | 340 |
Mass | (g) | 7301 |
Last update 05 Sep 2023
Notes
- Given the squared shape of the front window, the lens forms a rectangular image (Tech Info for related drawing).
- Working distance: distance between the front end of the mechanics and the object. Set this distance within ± 5% of the nominal value for maximum resolution and minimum distortion.
- Working f-number (wf/N): the real f-number of a lens in operating conditions.
- Maximum angle between chief rays and optical axis on the object side. Typical (average production) values and maximum (guaranteed) values are listed.
- Percent deviation of the real image compared to an ideal, undistorted image: maximum (guaranteed) values of the uncorrected image are listed.
- Residual distortion after calibration with TCLIB Suite software library, using a PTCP calibrations pattern and a fully GenICam compliant camera. For setup information see related table.
- Object side, calculated with the Rayleigh criterion with λ= 520 nm
- At the borders of the field depth the image can be still used for measurement but, to get a very sharp image, only half of the nominal field depth should be considered. Pixel size used for calculation is 3.45 μm.
- Indicates the availability of an integrated camera phase adjustment feature.
- Maximum dimension of the clamping flange.
- Measured from the front end of the mechanics to the camera flange.
All product specifications and data are subject to change without notice to improve reliability, functionality, design or other. Photos and pictures are for illustration purposes only.
Despite the efforts made to generate an error-free compatibility list, we always recommend to consult the Opto Engineering® technical support department before purchasing a compatible product. Opto Engineering® shall not be liable for any damage or malfunctioning caused by the incorrect selection of a compatible product.
ITA89-GM-10C
Area scan camera 4112 x 2176 MP, Sony IMX267, CMOS Global shutter, 1", Mono, 1 GigE, POE, C mount
ITA89-GC-10C
Area scan camera 4112 x 2176 MP, Sony IMX267, CMOS Global shutter, 1", Color, 1 GigE, POE, C mount
ITA120-GM-10C
Area scan camera 4112 x 3008 MP, Sony IMX304, CMOS Global shutter, 1.1", Mono, 1 GigE, POE, C mount
ITA120-GC-10C
Area scan camera 4112 x 3008 MP, Sony IMX304, CMOS Global shutter, 1.1", Color, 1 GigE, POE, C mount
ITA162-GM-20C
Area scan camera 5328 x 3040 MP, Sony IMX542, CMOS Global shutter, 1.1", Mono, 1 GigE, POE, C mount
ITA162-GC-20C
Area scan camera 5328 x 3040 MP, Sony IMX542, CMOS Global shutter, 1.1", Color, 1 GigE, POE, C mount
ITA204-GM-20C
Area scan camera 4512 x 4512 MP, Sony IMX541, CMOS Global shutter, 1.1", Mono, 1 GigE, POE, C mount
ITA204-GC-20C
Area scan camera 4512 x 4512 MP, Sony IMX541, CMOS Global shutter, 1.1", Color, 1 GigE, POE, C mount
LTCLCP144-G
Space-saving telecentric illuminator for LARGE FOV systems, minimun beam shape dimension 165 x 120 mm, green
PTCP-S1-HR1-C
Checkerboard calibration pattern for telecentric lens with certificate
PTCP-S1-HR1-P
Calibration pattern